Page 41 - iSEMconCatalog
P. 41

CALIBRATION DATA FILE FORMAT                      application. Our products should not be used in any
                                                                application where the failure or faulty performance
                                                                of the product might create a risk of personal injury
              Data file format stored in #####.cal              or death. Buyer assumes all risk of loss, damage or
                                                                injury alleged to arise from the failure or faulty per-
              Human readable ASCII file (text-file).            formance of an iSEM product in any unauthorized
              Standard delimiter is “,”.                        application. Buyer agrees to indemnify and hold
                                                                harmless iSEM, and its directors, employees,
              Freefield response data:                          agents, representatives and sales partners, from
                                                                and against any and all claims, costs, damages,
              www.iSEMcon.com   freefield                       losses and expenses including attorney fees which
              Sensitivity      30,88 mV/Pa @1kHz                arise from or are alleged to have been caused by
              10,00                 -0,02                       any claim for personal injury or death connected
              10,40                  0,03                       with buyer's use of an iSEM product in any unau-
              10,82                  0,06                       thorized application, including claims which allege
              11,26                  0,10                       that iSEM has been negligent in connection with
              11,71                  0,14                       the design or manufacture of the product.
              12,18                  0,17
              ……                                                iSEMcon GmbH
              ……………          0,94                               iSEMcon LLC
              19945,31             0,94                         (June 2nd 2010)
              19968,75             0,93
              19992,19             0,93
              ^ frequency (Hz)   ^amplitude response (dB)        IEC61672 Frequency response


                                                                IEC61672 class 1 frequency response
              Diffusefield response data derived from           Our microphones are known to have an
              freefield data ( 90 deg frequency response        IEC61672 class 1 frequency response or being
              measurement as per B&K literature)                close to the class 1 limits. This should not be mis-
                                                                understood. The entire microphone while build
              www.iSEMcon.com   diffusefield                    from electret condenser capsules using a metal-
              Sensitivity      30,88 mV/Pa @1kHz                ized polypropylene  diaphragm is not
              10,00                 -0,02                       class 1.
              10,40                  0,03                       Many competitive products even sold for USD
              10,82                  0,06                       1000 are using such prepolarized mylar dia-
              11,26                  0,10                       phragm microphone cartridges.
              11,71                  0,14                       Summarized: IEC 61672 class 1 addresses also
              12,18                  0,17                       the temperature and pressure behavior and is not
              ……                                                only limited to “domestic” conditions and fre-
              ……………          0,94                               quency response linearity.
              19945,31             2,94
              19968,75             2,93
              19992,19             2,93
              ^ frequency (Hz)   ^amplitude response (dB)      iSEMcon’s USER HINT – NO HOT PLUGGING

                                                                     The EMX-7150 or any other Phantom Pow-
              iSEMcon’s SAFETY CLAUSE                                ered Microphone should not be plugged or
                                                                     unplugged into a mixer console or PA sys-
                                                                tem unless the input channel is muted. If the sys-
                       Safety clause and unauthorized           tem does not have a muting option the volume
                      applications                              should be turned off. This avoids loud popping
                      Products manufactured and/or sold         noise that can cause damage in speakers and/or
              (herinafter products) by iSEMcon GmbH and/        affect your hearing.
              or iSEMcon LLC, (hereinafter iSEM) are not
              designed for use as a component in any life
              support, life safety, or other comparable





             www.iSEMcon.com                                                                                  Page 41
   36   37   38   39   40   41   42